MST
RFQ cartCart
Selection guide

Choose a power inductor from your circuit conditions

Pick the application and topology to see the MAZO families that fit, then request a quote.

No sign-up or email needed.
01TopologyBuck / SEPIC / PoC / common-mode
02Current & lossIrms / Isat / DCR / core loss
03EnvironmentHeat / height / EMI / grade
04Samples & priceDatasheet / lead time / price

Four common questions

Irms or Isat—which matters?

Both. Irms sets the temperature rise; Isat sets how far inductance drops at peak current. Test conditions differ by part.

Is lower DCR always better?

Lower DCR cuts I²R copper loss, but size, cost and core loss also count, more so at higher switching frequency.

Why start with topology?

Buck, SEPIC, Class-D, PoC and common-mode filters load the inductor differently. Inductance alone can point to the wrong family.

Does the selector pick the exact part?

No. It narrows the choice to a family. Final selection needs the part's datasheet, your controller's equations and a board test.

Six steps to the right part

  1. 01

    Define the operating point

    Input and output voltage, load, phase count, switching frequency and conduction mode.

  2. 02

    Work out ripple and peak current

    Use your controller's equations. For a buck, peak current is usually load current plus half the ripple.

  3. 03

    Check Irms and Isat separately

    Irms is the thermal limit; Isat is saturation at peak current. One does not replace the other.

  4. 04

    Estimate copper and core loss

    Start with I²R. At higher frequency, add AC winding loss and core loss.

  5. 05

    Add mechanical and environmental limits

    Height, footprint, land pattern, shielding, airflow, ambient temperature, vibration and qualification grade.

  6. 06

    Test samples on your board

    Check efficiency, temperature rise, ripple, transients and EMI, then confirm price and lead time.

01ΔIL ≈ (Vin − Vout) × Ton / LIdeal continuous-mode buck ripple; your controller's datasheet has the exact form.
02Ipeak ≈ Iout + ΔIL / 2Use peak current to check saturation margin.
03PDC ≈ Irms2 × DCRCopper loss only; add AC winding and core loss.
Inductor selector

Pick the family from your operating conditions, then request a quote

Start with the application. A general DC/DC rail or a BOM replacement also needs the topology.

What matters most (choose any)
More parameters (optional)

Matching families appear here

Each one lists why it fits, example part numbers and what to check before you choose.

By application

Full catalog
References

Where the equations come from

Equations and rating notes follow public application notes from Texas Instruments, Analog Devices and Coilcraft. Each part's datasheet is the final word.